Sources of Formaldehyde, Other Aldehydes and Terpenes in a New Manufactured House

Publication Type

Journal Article

Date Published

12/2002

Authors

DOI

Abstract

Formaldehyde, less volatile aldehydes, and terpene hydrocarbons are generally the predominant air contaminants in new manufactured and site-built houses. This study was conducted to identify the major sources of these compounds in a typically constructed, new manufactured house and to evaluate several source reduction practices. Specimens of materials used within the house were collected. These were individually pre-conditioned for 19 ± 4 days, and tested for emissions of formaldehyde and other target compounds using small-scale chambers. Several cabinetry materials, passage doors, and the plywood subfloor were the predominant sources of formaldehyde and other aldehydes. The plywood subfloor was the predominant terpene source. Whole-house emission rates for combined materials were predicted based on the emission factors and the corresponding material quantities. These predicted rates were compared with whole-house emission rates derived from measurements made at the house 3 months after its installation. For 10 of 14 target compounds including formaldehyde, the predicted and derived rates were within a factor of two. Four emission barriers applied to plywood were shown to reduce emission factors for formaldehyde, hexanal, and other aldehydes.

Journal

Indoor Air

Volume

12

Year of Publication

2002

Issue

4

Organization

Research Areas

Related Files